This chapter gives you a detailed Overview of the state of adaptation of PlantTools for Collaboration projects (BIM360/ACC).

The table below shows which PlantTools and Functions can either be already used (out of the box), or where you need only to handle some configuration files yourself, or which currently cannot be used att all.

This table is specifically for BIM360/ACC and Vault projects.

No

Doesn't currently work

Yes

Works without restrictions

Yes*1

Works with certain considerations

 

PlantTool

Function

Available for BIM/Vault

Remarks

PC_32x32-32

PlantCenter

All functions

No

We will probably discontinue PlantCenter for lack of use.

PCD_32x32-32

PlantClashDetection

Check of clashes

Yes

 

PDM_32x32-32

PlantDataManager

All features

Yes

The Not-Placed Objects (NPOs) are still a problem with BIM360/ACC projects when created in PlantDataManager.

PET_32x32-32

PlantExpressTools

Assemblies

Yes

 

PET_32x32-32

PlantExpressTools

Bolt Calculation

Yes

You have to handle the configuration files manually for now.

PET_32x32-32

PlantExpressTools

Calculations

Yes

 

PET_32x32-32

PlantExpressTools

Change Log

No

Needs to be redesigned. Not just because the way the changes are logged into just one database file, but also because of general performance issues.

PET_32x32-32

PlantExpressTools

Create Lists

Yes

 

PET_32x32-32

PlantExpressTools

Coordinates

Yes

 

PET_32x32-32

PlantExpressTools

DWG Export

Yes

Drawings to export must be available in your local project folder.

PET_32x32-32

PlantExpressTools

Export/Import Selection Lists

Yes

 

PET_32x32-32

PlantExpressTools

Export/Import Project Setup

Yes

 

PET_32x32-32

PlantExpressTools

Extended Assign Tag

Yes

 

PET_32x32-32

PlantExpressTools

Nozzle Check

Yes

 

PET_32x32-32

PlantExpressTools

Off-Page Connector Manager

No

Needs more work.

Currently you have to make sure, that the drawings where you want to connect OPC are already open and checked out. This includes also drawings which are triggered through PlantSpecDriven's AttributeFlow.

PET_32x32-32

PlantExpressTools

PlantProjectCreate

Yes

You can create a new project from a non BIM360/ACC project and then share this new project. But after it is shared you cannot use PlantProjectCreate for updating the BIM/ACC project.

PET_32x32-32

PlantExpressTools

PlantProjectManager

Yes

Some of the functions related to BIM360/ACC may not work yet a need to be reviewed.

PET_32x32-32

PlantExpressTools

PlantProjectSetup

No

Making changes to the Project Setup (Project & Drawing Properties) are currently not applied to the project.

Changes made to the PlantTools settings (Bolt Calculation, Change Log, OPC Manager) are only applied locally, but not checked in.

PET_32x32-32

PlantExpressTools

Properties Palette

Yes

 

PET_32x32-32

PlantExpressTools

Rename/Copy Project

Yes

Currently you have to create a project backup, then copy or rename and then share the project again.

PET_32x32-32

PlantExpressTools

Rule-Based block insert

Yes

Currently you have to make sure, that the drawing in which the blocks will be inserted are already checked out.

PET_32x32-32

PlantExpressTools

Selection List Update

Yes

 

PET_32x32-32

PlantExpressTools

SymbolsPalette

Yes

 

PET_32x32-32

PlantExpressTools

Update Acquisition Rules

Yes

 

PET_32x32-32

PlantExpressTools

Update From/To

Yes

Since From/To also updates line segments connected with Off-Page Connectors the function offers to open the connected drawing. You have to make sure that involved drawings are already checked out.

PET_32x32-32

PlantExpressTools

Update Line Annotation

Yes

 

PET_32x32-32

PlantExpressTools

Update Tags

Yes

 

PL_32x32-32

PlantLink

All features and configuration files

Yes

 

PR_32x32-32

PlantReporter

All features

Yes

What is missing is the handling of the report configuration files if they are in the project.

Also creating versions/revisions and comparing report versions/revisions is deactivated, because we need to store the info in a new way.

PSD_32x32-32

PlantSpecDriven

All features

Yes

What is missing are all function which open drawings (e.g. using Open in PlantSpecDriven Tree). And which change Project Setup and Pipe Specs.

Also AttributeFlow's Task List is not adapted.

Currently you have to make sure, that the drawings which you need to have open, or opened by you.

PS_32x32-32

PlantSync

All features

No

Currently you have to create project backups of all projects you want to synchronize (the target projects in PlantSync). Then you can use PlantSync and then share the projects again.