The left toolbar looks like this:

PET OPCM UI 002

The state of the three toggle buttons marked above will be stored. So when you close and open the OPC Manager or even restart Plant 3D, the states of those toggle buttons are restored to the last known setting.

Open PlantProjectSetup

The first button allows you to open PlantProjectSetup. For example, when you want to make changes to the setup of the OPC Manager.

PET OPCM UI 003

Refresh Trees

In case you need to refresh the trees you can use the Refresh button. Although, the trees should always be up-to-date.

PET OPCM UI 004

Filter by State

You can filter both trees by selecting a state from the dropdown list.

Show All

Shows all OPC nodes.

Show all Conflicts

Shows all OPC nodes which have either 'Inconsistency', or 'Unknown Flow Direction', or 'Flow Direction Conflict', or 'Attribute Flow TaskList' status..

Unconnected

Shows all Unconnected OPC nodes.

Connected

Shows all Connected OPC nodes.

Inconsistencies

Shows all Connected OPC nodes where at least one property value differs.

Connected to other Project

Not implemented yet.

Connected to other Project with Inconsistencies

Not implemented yes.

Unknown Flow Direction

Shows all OPC nodes with an unknown Flow Direction. This happens when you have a line segment connected to an OPC on one side, but the line segment is not connected on the other side.

Flow Direction Conflict

Shows all OPC nodes where there is a conflict with the Flow Direction. This happens when the connected line segments have different flow directions.

Attribute Flow TaskList

Shows all OPC nodes which have a pending Task in the AttributeFlow task list.

PET OPCM UI 058

For example, if you want to see only the OPCs which have an 'Unknown Flow Direction'.

PET OPCM UI 005

You see the selected state in the toolbar and the trees only show the OPCs with this state.

A little warning. If the trees are filtered for a specific state and then the state of an OPC changes, the OPC disappears.

PET OPCM UI 006

If you want to see all OPCs again you select 'Show All'.

PET OPCM UI 007

And they are back.

PET OPCM UI 008

Show/Hide drawing nodes

By default the tree shows the folders/drawing as the first level and then the OPCs nodes as the leafs of the tree.

If you click on the 'Hide Drawings' button...

PET OPCM UI 009

...the folders and drawings will be hidden and what's left are the OPCs.

PET OPCM UI 010

If you click on the button again...

PET OPCM UI 011

...the folders and drawings will appear again.

PET OPCM UI 012

Show/Hide filtered nodes

When you have set a filter expression, the OPC which are supposed to be filtered-out of the trees show up as greyed out. If you click on the 'Hide filtered' button...

PET OPCM UI 013

...those OPCs are no longer visible.

PET OPCM UI 014

If you click on the button again...

PET OPCM UI 015

...the OPCs appear again.

PET OPCM UI 016

Disable/Enable colored OPC Symbols

The last toggle button (with the red OPC icon) allows you to uncolor the OPC symbols in the drawings. This feature is the same technology of the PID Painter in Plant 3D. If you click on this button...

PET OPCM UI 022

...the OPCs appear in the color set in Project Setup (in this case White).

PET OPCM UI 023

If you click on the button again...

PET OPCM UI 024

...the OPCs will be colored again according to their state shown in the trees.

PET OPCM UI 025

Update OPC Properties

The OPCs get two new properties. The properties are typically filled out automatically when working with the OPC Manager. However, it can happen, that the properties are not filled out with the correct values.

PET OPCM UI 026

If you click on the button, these two properties will be filled out for the whole project. Whatever values are currently in the properties, will be overridden.

PET OPCM UI 027

There is just one exception. In case you set a user defined state which is not one of the default states. If an OPC has a user defined state, this state will not be overridden.

PET OPCM UI 028

Enable/Disable Drawing Preview

In case the drawing viewer isn't needed, you can click on the toggle button in the toolbar.

PET OPCM UI 054

Now the viewer is disabled. If you click on the button again you can enable the viewer again.

The advantage to disable the viewer is, that the drawings aren't locked when shown in the viewer.

PET OPCM UI 055

AttributeFlow Task Dialog

In case you use PlantSpecDriven and there are tasks from the AttributeFlow pending, the icon in the toolbar to open the AttrbiteFlow Task dialog will be enabled.

PET OPCM UI 056

If you click on it, you will see the outstanding tasks.

PET OPCM UI 057

Since using OPC Manager together with PlantSpecDriven's AttributeFlow is very specific we have a separate chapter for it under Use with AttributeFlow.

Status bar

For bigger projects with thousands of OPCs you will see that the status bar at the lower left hand corner of the OPC Manager, will show a progress bar where you can interrupted the updating process. However, even for a project with 6.200 OPCs it takes about 10 sec to update all OPCs.

PET OPCM UI 042