Hand Valves Class

<< Click to Display Table of Contents >>

Navigation:  PlantSpecDriven > How to use > Configuration > P&ID Properties >

Hand Valves Class

Previous pageReturn to chapter overviewNext page

Size2/Size3/SizeX (mandatory when using Assign Catalog Data or AttributeFlow)

With the exception of Reducers and Relief Valves all other classes have just Size by default. The AttributeFlow and Assign Catalog Data features can handle multiple Sizes. One for each AttachmentPoint/Port of your Symbol. This means, that even a straight Valve Symbol can have two different sizes. This can be the case if you have a Pressure Reducing Valve. Another example would be a 3-Way Valve where the branch may have a different Size than the AttachmentPoints left and right.

Remark: We limited the documentation to Size2, Size3, and Size4. If you have multi-port valves which require sizes up to 6 you simply add more sizes. The naming is limited to the Format SizeX (where X is an integer from 3 to 6).

PSD_Sx_EndType & PSD_Sx_NominalDiameter (mandatory when using AutoPipe)

These properties will contain the EndTypes and NominalDiameters of a selected Part in order for AutoPipe to add the appropriate Flanges/Fasteners. As with the SizeX property you may want to add EndType and NominalDiameter properties for each AttachmentPoint.

PSD Config 014

Next Chapter: Piping Fittings Class